Specifications
Getting Started 1 - 7
Digital Scanner Cradle
The digital scanner CR0078-S and CR0078-P cradles serve as a stand, charger, and host interface for the digital
scanner. The cradle sits on a desktop. The CR0078-S cradle can also be mounted on a vertical surface (such as a
wall). For more information about mounting options and procedures, refer to the documentation included with the
cradle.
The CR0078-S cradle is available as a charging cradle with a radio and as a charge-only cradle. The CR0078-P
cradle is only available as a charging cradle with a radio. The differences between the two versions are as follows:
•
Charging cradle with radio: When the cordless digital scanner is paired to the cradle, all communication
between the digital scanner and the host computer is accomplished through the cradle. Each bar code
contains programming instructions or other data unique to the bar code pattern. The digital scanner is paired
to the cradle and transmits bar code data to the cradle via Bluetooth Technology Profile Support. The cradle
then sends that information via an interface cable to the host computer for interpretation.
•
Charge-only cradle: This cradle serves as a stand and battery charger. It does not contain a radio and has
no communication capability.
The following table outlines several main differences between the CR0078-S and CR0078-P cradles:
Table 1-1
Cradle Features
NOTE For more information about communication between the digital scanner, cradle and host, see Chapter 4,
Radio Communications.
Feature CR0078-S CR0078-P
Scanning Hand-Held scanning Hands-Free or Hand-Held scanning
Bluetooth Bluetooth or Charge Only (CR0008-S) Bluetooth
Pairing Pair up to 3 scanners per cradle Pair up to 7 scanners per cradle
Paging Not available Ability to page misplaced scanner(s)
Charging
Charges via USB with no power supply required;
requires ferrite if used with a 5V power supply in
a healthcare environment
Requires 12V power supply
Interfaces
Supports most commonly used interfaces (see
Technical Specifications on page 3-9 for detailed
list)
Supports most commonly used interfaces with the
exception of Wand Emulation, Scanner Emulation
and Synapse
FIPS Not available FIPS140-2 wireless security
USB Cable Standard universal USB cable
Requires universal cables with shielded modular
plugs
Image Capture Not available Supported via SNAPI
OCR/MICR Not available Supported via SNAPI