Operating instructions

Bench Setup and Operation 3-37
SG4000 Installation and Operation Manual
Figure 3-34 illustrates the segmented return plug-in board.
Figure 3-34
Segmented return board
TX1
SM
TX2
R1
J3
J5
R4
R7
R6
R9
R8
J7
J4
IN2 IN1
R5
R2
R3
T1
R10
J6
C12 C12
C11
C7
C4
C9
C10
C6
C8
C3
C2
C1
R11
Figure 3-35 illustrates the signal flow through the segmented return board.
Figure 3-35
Segmented return board – signal flow
-0.5dB
Loss = 0.9 dB
TX1
TX2 IN2
IN1
SM
Pad
Pad
To set up the segmented return option:
1 Confirm that return transmitters are installed in lid optics slots 3, 4, 5, and 6.
2 Confirm that a segmented return board is installed in the return configuration locations 2
and 3, as illustrated in Figure 3-33.
3 Connect an RF cable from the segmented return board in configuration location 2 to the
transmitters in lid optics slots 3 and 4.
4 Connect an RF cable from the segmented return board in configuration location 3 to the
transmitters is lid optics slots 5 and 6.
The RF cable should be approximately five inches long and have red boots on the connector
signifying the return path.
5 Connect the appropriate return RF cables from the SG4-RF modules to each segmented
return board.
In a typical installation, the RF modules in Ports 1 and 3 are connected to the segmented
return board in return configuration location 3. The RF modules in Ports 4 and 6 are
connected to the segmented return board in return configuration location 2.
6 Ensure that the PIC cable is properly connected to the lid and power distribution board in
the housing base.
7 Route and connect the fiber service cable.