Installation guide
5-44 Motorola RF Switch System Reference
4. Refer to the following redundancy member information:
IP Address Displays the IP addresses of the members of the redundancy group. There are a
minimum of 2 members needed to define a redundancy group, including this
current module.
Status
Displays the current status of this group member. This status could have the
following values:
• Configured - The member is configured on the current wireless service
module.
• Seen - Heartbeats can be exchanged between the current switch and this
member.
• Invalid - Critical redundancy configuration parameter(s) of the peer
(heartbeat time, discovery time, hold time, Redundancy ID, Redundancy
Protocol version of this member) do not match this switch’s parameters.
• Not Seen - The member is no more seen by this switch.
• Established - The member is fully established with this current module
and licensing information already been exchanged between this switch
and the member.
AP Adoption Count Displays the number of Access Ports adopted by this member.
AAP Adoption Count Displays the number of Adaptive Access Ports adopted by this member.
Adoption Capacity Displays the maximum number of Access Ports this member is licensed to adopt.
For information on licensing rules impacting redundancy group members, see
Redundancy Group License Aggregation Rules on page 5-46.
AP License Count Displays the number of Access Port licenses available for this switch. For
information on licensing rules impacting redundancy group members, see
Redundancy Group License Aggregation Rules on page 5-46.
AAP License Count Displays the number of Adaptive Access Port licenses available for this switch. For
information on licensing rules impacting redundancy group members, see
Redundancy Group License Aggregation Rules on page 5-46.
Image Version Displays the image version currently running on this member. Is the selected
version complimentary with this switch’s version?
First Seen Displays the time this member was first seen by the switch.
Last Seen Displays the time this member was last seen by the switch.
Mode The Redundancy Mode could be Active or Standby depending on the mode
configuration on the member. Refer to the Configuration screen to change the
mode
HB Sent Displays the number of heartbeats sent from the switch to this member since the
last reboot of the switch.
HB Received Displays the number of heartbeats received by the switch since the last reboot.
Updates Sent Displays the number of updates sent from the switch since the last reboot.
Updates include, authorization level, group authorization level and number of
Access Ports adopted.