7. The Monitoring/Recovery Configuration section contains the following configuration items:
8. The Diagnostic Configuration section contains the following two configuration items:
9. The Calibration Schedule contains the following calibration settings:
Assign - Tx Power Check this box to enable automatic assignment of transmit power.
Assign - Rescuers Check this box to enable automatic assignment of rescuers along with rescuing
power.
Available The Available box lists all available channels for Smart RF.
Configured The Configured box lists all channels enabled for Smart RF.
Add To add a channel to the configured list, select one or more channel from the
Available box and click the Add button.
Remove To remove a channel from the configured list, select one or more channels from
the Available box and click the Remove button.
Number of Rescuers Assign a number of radios to dedicate as rescuers. The valid range is between 1
and 5.
Retry Threshold (avg
attempts/pkt)
Specify the retry threshold which is the average number of retries per packet to
cause a radio to re-run channel selection.
Hold Time (seconds) Specify the global hold time in seconds. The valid range is between 30 and 65535
seconds.
Assignable Power
Range (dBm)
Specify a valid range for the power in dBm. The valid minimum is 4 and maximum
is 20.
Scan Dwell Time
(seconds)
Specify the RF Scan Dwell Time in seconds. The valid range is between 1 and 10
seconds.
Interference
Recovery
Check this box to enable monitoring for interference and self-healing it by rescuer.
Faulty Radio
Recovery
Check this box to enable monitoring for defective radio and self-healing by its
rescuer.
Coverage Hole
Recovery
Check this box to enable monitoring and recovering for coverage holes.
Verbose Mode Check this box to enable verbose diagnostic information for Smart RF.
Extensive Scan
Mode
Check this box to enable extensive scan mode when using Smart RF.
Schedule Calibration Check this box to enable scheduled RF Calibration.
Start Date If scheduled RF Calibration is enabled, enter a start date in MM/DD/YY format for
the start date of scheduled calibration.