A power supply is included, however a power cord is not supplied with the switch. Use only a
correctly rated power cord certified (as appropriate) for the country of operation
.
2.2.1 Power Protection
If possible, use a circuit dedicated to data processing equipment. Commercial electrical
contractors are familiar with wiring for data processing equipment and can help with the load
balancing of these circuits.
Install surge protection. Be sure to use a surge protection device between the electricity
source and the RFS4010 RF Switch.
Install an Uninterruptible Power Supply (UPS). A UPS provides continuous power during a
power outage. Some UPS devices have integral surge protection. UPS equipment requires
periodic maintenance to ensure reliability. A UPS of the proper capacity for the data processing
equipment must be purchased.
Width 304.8mm (12.0in)
Height 44.45mm (1.75 in) 1 RU
Depth 254mm (10.0 in)
Weight 2.15 Kg (4.75 lbs)
Operating Temperature 0°C - 40°C (32°F - 104°F)
Operating Humidity 5% - 85% RH, non-condensing
Operating Altitude 10,000 ft @ 28deg C < 15% Relative Humidity