user manual

1-52 Computer Group Literature Center Web Site
Hardware Preparation and Installation
1
the 14-pin combined LED-mezzanine/remote-reset connector, J1. The FUS
LED (DS5) on the MVME2603/2604 front panel illuminates when all
three voltages are available.
In MVME712M I/O mode, the MVME2603/2604 supplies SCSI
terminator power through a 1A fuse (F1) located on the P2 adapter board.
If the fuse is blown, the SCSI device(s) may function erratically or not at
all. With the P2 adapter board cabled to a transition module and with an
SCSI bus connected to the transition module, the green
SCSI LED on the
module illuminates when SCSI terminator power is available. If the
SCSI
LED on the transition module flickers during SCSI bus operation, check
fuse F1 on the P2 adapter board.
Note Because any device on the SCSI bus can provide the
TERMPWR
signal, and because the MVME2603/2604
FUS LED monitors the
status of several voltages, the LED does not directly indicate the
condition of any single fuse. If the
FUS LED flickers or goes out,
check all the fuses (polyswitches).
In MVME761 I/O mode, the MVME2603/2604 supplies SCSI terminator
power through a polyswitch (resettable fuse) located on the P2 adapter
board.
The MVME2603/2604 base board supplies a
SPEAKER_OUT signal to the
14-pin combined LED-mezzanine/remote-reset connector, J1. When J1 is
used as a remote reset connector with the LED mezzanine removed, the
SPEAKER_OUT signal can be cabled to an external speaker. For the pin
assignments of J1, refer to Table 4-1 on page 4-3.
On the MVME2603/2604 base board, the standard serial console port
(
COM1) serves as the PPCBug debugger console port. The firmware
console should be set up as follows:
Eight bits per character
One stop bit per character
Parity disabled (no parity)
Baud rate of 9600 baud