User`s manual
CNFG - Configure Board Information Block
3-31
3
needs to be done if the firmware complains that there is
a mismatch in values. To correct it, invoke CNFG;M
from the firmware command line to correct the
mismatched values.
Examples
Example 1: Shown below is a sample of a valid board information
block:
PPC1-Bug>CNFG <Return>
Board (PWA) Serial Number = “MOT000061050”
Board Identifier = “MVME2603-001”
Artwork (PWA) = “01-W3015F01A”
MPU Clock Speed = “233”
Bus Clock Speed = “067”
Ethernet Address = 08003E20C983
Primary SCSI Identifier = “07”
System Serial Number = “163725”
System Identifier = “Motorola Series E603-166P”
License Identifier = “12345678”
PPC1-Bug>
Example 2: Shown below is a board information block with
corrupted data.
PPC1-Bug>CNFG <Return>
WARNING: Board Information Block Checksum Error
Board (PWA) Serial Number = "????????????"
Board Identifier = "????????????????"
Artwork (PWA) Identifier = "????????????????"
MPU Clock Speed = "????"
Bus Clock Speed = "????"
Ethernet Address = 000000000000
Primary SCSI Identifier = "??"
System Serial Number = "?????????????"
System Identifier = "?????????????????????????"
License Identifier = "12345678 "
PPC1-Bug>