User`s manual

.PFLASH Function
5-77
5
Field descriptions:
Control/Status
Word
SpeciÞes control and status of the various phases
of the Flash memory programming. This
parameter has two 16-bit parts: bits #31 to #16
specify status and bits #15 to #0 specify control.
Source Starting
Address
Specifies the source starting address of the
data with which to program the Flash
memory. Word (32-bit) address alignment is
required for this parameter.
Number of Bytes
to Program
Specifies the number of bytes of the source
data (or the number bytes to program the
Flash memory with). Word (32-bit) address
alignment is required for this parameter.
Destination
Starting Address
Specifies the starting address of the Flash
memory to program the source data with.
Word (32-bit) address alignment is required
for this parameter.
Instruction
Execution
Address
Specifies the instruction execution address
to be executed upon completion of the Flash
memory programming. This parameter
must meet the syntax of the reset vector of
the applicable MPU architecture of the host
product. This parameter is qualified with a
control bit in the control/status word;
execution will only occur when the control
bit is set and no errors occur during
programming/verification. This non-
execution on error can be invalidated by yet
another control bit in the control/status
word.