User`s manual

NIOT - Network I/O Teach (Configuration)
3-159
3
Boot File Name (“NULL” for None) =?
The name of the boot file to load. Once the file is loaded, control
is passed to the loaded file (program). To specify a null
filename, the string ÒNULLÓ must be used; this resets the
filename buffer to a null character string.
Argument File Name (“NULL” for None) =?
The name of the argument file. This file may be used by the
booted file (program) for an additional file load. To specify a
null filename, the string ÒNULLÓ must be used; this resets the
filename buffer to a null character string.
Boot File Load Address =001F0000?
Boot File Execution Address=001F0000
The load and execution addresses of the boot file.
Boot File Execution Delay =00000000?
The delay, in seconds, before control is passed to the loaded file
(program).
Boot File Length =00000000?
The number of bytes from the data transfer address to transfer.
A length of 0 speciÞes to transfer the entire Þle on a read. On a
write the length must be set to the number of bytes to transfer.
Boot File Byte Offset =00000000?
The offset into the Þle on a read. This permits users to wind into
a Þle.
BOOTP/RARP Request Retry =00?
TFTP/ARP Request Retry =00?
The number of retries that should be attempted prior to giving
up. A retry value of zero specifies always to retry (not give up).