Fixed-mount Imager Integration Guide

11 - 2 Symbol MS4404/MS4407 Integration Guide
Imaging Sequence Examples
In most cases, capturing one bar code sets the parameter value. For example, to transmit bar code data without
the UPC-A check digit, simply capture the Do Not Transmit UPC-A Check Digit bar code under Transmit UPC-A
Check Digit on page 11-14. The imager issues a fast warble beep and the LED turns green, signifying a successful
parameter entry.
Other parameters, such as Set Length(s) for D 2 of 5 require capturing several bar codes. See the individual
parameter, such as Set Length(s) for D 2 of 5, for this procedure.
Errors While Imaging
Unless otherwise specified, to correct an error during an imaging sequence, just re-capture the correct parameter.
Symbology Parameter Defaults
Table 11-1 lists the defaults for all symbologies parameters. To change any option, capture the appropriate bar
code(s) provided in the Symbologies Parameters section beginning on page 11-7.
NOTE See Appendix A, Standard Defaults for all user preferences, hosts, and miscellaneous default parameters.
Table 11-1
Symbology Default Table
Parameter
Parameter
Number
Default
Page
Number
UPC/EAN
UPC-A 01h Enable 11-7
UPC-E 02h Enable 11-7
UPC-E1 0Ch Disable 11-8
EAN-8/JAN 8 04h Enable 11-8
EAN-13/JAN 13 03h Enable 11-9
Bookland EAN 53h Disable 11-9
Decode UPC/EAN/JAN Supplementals
(2 and 5 digits)
10h Ignore 11-10
User-Programmable Supplementals
Supplemental 1:
Supplemental 2:
F1h 43h
F1h 44h
11-13
UPC/EAN/JAN Supplemental Redundancy 50h 10 11-14
Transmit UPC-A Check Digit 28h Enable 11-14
Transmit UPC-E Check Digit 29h Enable 11-15