Specifications

10 - 2 Symbol MiniScan MSXX04 Series Integration Guide
Operational Parameters
MiniScan scanners are shipped with the default settings shown in Table 10-1 on page 10-2. These default values
are stored in non-volatile memory and are preserved even when the scanner is powered down.
There are two ways to change the default values:
Scan the appropriate bar codes in this chapter. These new values replace the standard default values in
memory. To recall the default parameter values, scan the Set All Defaults bar code on page 10-8.
Download data through the scanner’s serial port using Symbol’s Simple Serial Interface (SSI). Hexadecimal
parameter numbers are shown in this chapter below the parameter title, and options are shown in
parenthesis beneath the accompanying bar codes. See the Simple Serial Interface (SSI) Programmer’s
Guide for detailed instructions for changing parameters using this method.
Default Table
Table 10-1 lists the defaults for all parameters, and the page number each parameter appears on. To change any
option, scan the appropriate bar code(s).
Table 10-1
Default Table
Parameter
Parameter
Number
Default
Page
Number
Set Default Parameter All Defaults
10-8
Scanning Options
Beeper Volume 8Ch High Volume
10-10
Beeper Tone 91h High Frequency
10-11
Beeper Frequency Adjustment F07 91h 2500 Hz
10-11
Laser On Time 88h 3.0 sec: MS954
5.0 sec: MS2204; MS2204VHD;
MS3204
10-12
Scan Angle
(MS1204FZY and MS954 only)
BFh
Wide
10-12
Power Mode 80h Low Power
10-13
Trigger Mode 8Ah Level
10-14
Scanning Mode (MS2204,
MS2204VHD, and MS3204 only)
8Dh Smart Raster
10-15
Aiming Mode F0h 7Eh Disabled
10-16
Raster Height (MS2204, MS2204VHD,
and MS3204-I000 only)
E4h 15
10-17
Raster Expansion Rate (MS2204,
MS2204VHD, and MS3204-I000 only)
E5h 11
10-17