Specifications
Maintenance and Troubleshooting 9 - 3
Scanner does not function. Accidentally scanned
Host
Trigger
,
Level Trigger
, or
Pulse Trigger
from
Trigger
Options on page 3-5
.
Download the SSI Demonstration Utility for
MiniScan from
http://www.symbol.com/contactsupport.
Install the utility, then use the utility to change the
Trigger Mode
parameter 138 (8Ah) to the value
04h (Continuous Mode) via SSI. See
Chapter 11,
Simple Serial Interface (SSI)
, and
Trigger Modes
on page 10-14
.
Alternatively, use the utility's soft trigger button to
activate the scanner, and scan the
Continuous
option of the
Trigger Mode
parameter.
Note that this utility does not work with Motorola’s
non-handshaking interface cable
(p/n 25-63736-01R).
Connect an interface cable which has an external
trigger jack, a push button trigger cable, and a
power supply to the scanner. You can purchase
these cables from Motorola, or make a similar one
using the scanner’s pinouts as a reference. See
the specification chapter for your MiniScan model
for pinouts.
Using a momentary switch, short the scanner’s
trigger line to ground to activate the laser, then
scan the
Continuous
option of the
Trigger Mode
parameter.
Table 9-1
Troubleshooting
Problem Possible Cause Possible Solutions
NOTE If after performing these checks the symbol still does not scan, contact the distributor or call Motorola
Enterprise Mobility Support at the telephone number listed on
page xv.