User Guide

A-2
Specifications
A
Environment
Connectors and Cables
Table A-2. Environmental Specifications
Item Mode Minimum Maximum
Temperature Operate 0
o
C (32
o
F) 55
o
C (131
o
F)
Storage -20
o
C (-4
o
F) 70
o
C (158
o
F)
Relative Humidity
(non-condensing)
Operate 10% 90%
Storage 5% 95%
Altitude Operate Sea level 15,000 feet
Storage Sea level 50,000 feet
Table A-3. Connector and Cable Requirements
Item
Requirement
Connectors 68-pin Euro style SCSI:
Shielded - external or internal cabinet applications
Non-shielded - internal cabinet applications only
Bus Cable 68-conductor, flat ribbon or discrete wires:
Single-ended applications:
Type - twisted pair only
Shielding - match with connector
Max bus length - 6 meters
Differential applications:
Type - twisted pair only
Shielding - match with connector
Max bus length - 25 meters