Technical data

Cabling
5-23
5
Dual 9-, 12-, and 20-Slot Chassis Cabling
Control Cables (12- and 20-Slot Systems without Alarm Board)
Use the following instructions to install the control cables.
1. Plug the end of an EIA-232-D cable into the host port of the
terminal to be used as the system console.
2. Plug the other end of the cable into the transition module
connector marked
CONSOLE or SERIAL PORT 1 on the back of
the system.
3. If an SCSI peripheral expansion enclosure is present, connect
it to the system as follows:
Attach one end of an SCSI cable to one of the 68-pin
connectors labeled SCSI on the back of the peripheral
expansion enclosure (Figure 5-7).
Select a transition module connector labeled
SCSI or SCSI
OUT on the back of the system. Remove the terminator
block and plug the other end of the SCSI cable into the
connector. Move the terminator block to the unused
connector on the peripheral expansion enclosure.
If you have the Environmental Monitor option, install an
RJ45 cable between the connector on the back of the
system (identified with a “no telephone” graphic) and
either of the RJ45 connectors on the back of the peripheral
expansion enclosure.
4. Cable all other associated equipment (terminals, printers,
SCSI expansion peripherals, and so on) to the system as
described in the installation guides for those peripherals.