Technical data
5-18
Site Preparation and Installation
5
Data/Control Cables (with Alarm Board)
Refer to Figure 5-6 on page 5-19 while following these procedures.
1. Plug the end of an EIA-232-D cable into the host port of the
terminal to be used as the system console.
2. Plug the other end of the cable into the transition module
connector marked
CONSOLE or SERIAL PORT 1 on the back of
the system.
3. If a SCSI Device Storage Module is present, connect it to the
system as follows:
– Attach one end of a SCSI cable to one of the 68-pin
connectors labeled SCSI on the back of the Storage Module.
– Select a transition module connector labeled
SCSI IN or OUT
on theback of the system. Remove the terminator block
and plug the other end of the SCSI cable into the
connector. Move the terminator block to the unused
connector on the Storage Module.
4. Cable all other associated equipment (terminals, printers,
SCSI expansion peripherals, etc.) to the system as described
in the installation guides for those peripherals.