Technical data
4-18
SCSI Device Storage Module
4
Power Supply Removal and Replacement
The power supply module (Figure 4-6 on page 4-19) is installed at
the right side of the drive bays in the module’s chassis. The power
supply receives –48Vdc or 115/230Vac input power directly
through its back panel. The power supply outputs are cabled to the
cooling fan and to a backplane connector, which applies operating
voltages from the power supply to the mass storage modules.
!
Caution
Removal of a power supply module involves exposure
to high voltages. Avoid touching the connectors. Allow
one minute for the capacitors in the power supply to
discharge.
The suggested procedure for removal and replacement of the
module’s power supply module is as follows:
Removal
1. Switch the power supply of the host system to
STANDBY.
2. Disconnect the input power source from the module’s
chassis:
– If the power supply is an AC unit, unplug the power cord
from the AC outlet (the other end of the cord disconnects
automatically when you remove the module from the
chassis).
– If the power supply is a DC unit, turn off the –48Vdc
power source and unplug the DC connector from the
power supply input.
3. After waiting for the power to fully discharge from the
supply, remove the module’s bezel, if installed.
4. At the upper right corner of the power supply module, loosen
the captive screw that holds the module in the chassis.