User`s guide

Technician Mode
68P02953C05 12-13
12.6. RECOVERY MODE
The Recovery Mode command enables the user to program technician parameters without loading them
previously from the radio. To open the Recovery Mode dialog box, from the Technician menu, choose
Recovery Mode (ALT, S, T, R).
WARNINGS
1. Do not use this command unless the radio is malfunctioning or it
indicates a data base problem.
2. When using the Recovery Mode the radio may not be calibrated.
Figure 12-15. Recovery Mode Dialog Box
12.6.1. Enable Calibration Parameters Update
In order to perform technician utilities, the user has to load technician parameters from the radio ( using
the Read Device command).
To bypass this requirement and perform technician utilities based on file loaded parameters, you may
use the first line of the Recovery Mode dialog box. After checking this box, the Status line is updated
to “radio”, simulating that the technician parameters were loaded from the radio.
12.6.2. Ignore Radio Code When Writing To Radio
When you load parameters into the radio (using the Write Device command), a self test is performed.
This test checks if the parameters loaded into the radio were previously read from the same radio. You
may bypass this test by checking the second line on the Recovery Mode dialog box.
Click to perform technician utilities on file loaded parameters.
Click to cancel Write Device self test.