Technical data
3-30 Computer Group Literature Center Web Site
Test Descriptions
3
Prior to the execution of any of the EIDE tests, a validity check is
performed on the CLUN/DLUN pair specified by the EIDE “cf”
parameters. If either one of the values provided is invalid, the test aborts
and an error message is displayed.
General Configuration Description:
The EIDE diagnostics require some manual setup using the “cf” command
prior to execution. The default values are shown below:
Before running these tests, make sure that the CLUN/DLUN fields have
valid data as illustrated in Step 1 below. Additional parameters may be
changed as shown in Step 2 through Step 6.
PPC1-Diag>cf eide
EIDE Configuration Data:
EIDE CLUN =00 ?
EIDE DLUN [00 - 70] =00 ?
Test Sector Number (start) =00000000 ?
Number of Sectors To Test (Sector Size: HD = 256, CD-ROM =2048)
=00000001 ?
Fill Data =0000 ?
Test Data Increment/Decrement Step =0001 ?
Enable Destructive Tests (R/W, DMA) [Y/N] =N ?
PPC1-Diag>
1. EIDE CLUN and DLUN Fields.
The “EIDE CLUN and DLUN” fields are the most important fields in the
“cf” EIDE setup since they specify which drive is tested. The best way to
determine CLUN and DLUN field values for use in the “cf” setup is to run
the “ioi” command.
PPC1-Bug>ioi
I/O Inquiry Status:
CLUN DLUN CNTRL-TYPE DADDR DTYPE RM Inquiry-Data
1 0 PC8477 0 $00 Y <None>
14 0 PBC-EIDEF1 0 $00 N WDC AC21200H 1E55
PPC1-Bug>
2. Test Sector Number Field.
The “Test Sector Number” field specifies a sector number to be used as a
starting location for several of the EIDE tests.