Technical data
3-28 Computer Group Literature Center Web Site
Test Descriptions
3
PCI Config Header Interrupt
Line error.
Written Value = 0xXX
Read Value = 0xXX
Value written to the PCI header Int Line register does not
match the value read back.
MDI control register error Value written to the MDI control register does not match the
value read back.
CU unexpectedly active Command Unit expected to be idle or suspended but is
actually active.
Device self diagnostic reports
failure
Self diagnose command reports failure.
RX header destination address
mismatch
Received loopback packet header destination address does
not match the one transmitted.
RX header source address
mismatch
Received loopback packet header source address does not
match the one transmitted.
RX header type mismatch Received loopback packet header TYPE field does not
match the one transmitted.
RX data mismatch
Iteration = NN
Element = NN
Value sent = 0xXX
Value received = 0xXX
Received loopback packet data portion does not match the
one transmitted.
No interrupts detected No interrupts were detected by the MPU and handler was
not invoked.
Unexpected number of received
packets.
Expected pckts = NN
Received pckts = NN
Number of correctly received loopback packets does not
match the number that was requested for.
Undefined program error Software detected an undefined error.
Table 3-6. INET Error Messages (Continued)
Error Message Symptom or Cause