Technical data

3-26 Computer Group Literature Center Web Site
Test Descriptions
3
Response/Messages
After the command is issued, the following line is printed:
INET SPACK: Single Pkt Interrupt LB Testing. Running-->
If all parts of the test are completed correctly, the test passes:
INET SPACK: Single Pkt Interrupt LB Testing. Running->PASSED
If any part of the test fails, the display appears as follows:
INET SPACK: Single Pkt Interrupt LB Testing. Running->FAILED
INET/SPACK Test Failure Data:
(
error message
)
Refer to the section INET Error Messages for a list of the error messages
and their meaning.
INET Error Messages
The INET test group error messages generally take the following form:
INET SPACK: Single Pkt Interrupt LB Testing. Running-->FAILED
INET/SPACK Test Failure Data:
RX data mismatch
Iteration = NN
Element = NN
Value sent = 0xXX
Value received = 0xXX
The first line of the test failure data identifies what type of failure occurred.
The following line provides additional information about the failure.