Technical data
3-8 Computer Group Literature Center Web Site
Test Descriptions
3
CNCTR - Connector
Command Input
PPCx-Diag>dec cnctr
Description
This test verifies that the data path through the external (AUI
or TP (twisted pair)) connection is functional, by transmitting and
receiving packets and comparing the data. This test requires the presence
of an external loopback “plug” for AUI or TP.
Note It is recommended that the board under test not be connected to a
live network while this test is running. The suggested “loopback”
setup for AUI is an AUI-to-thinnet transceiver attached to a BNC
tee with terminators on each arm of the tee. For TP setup, an
external shunt needs to be put in the TP socket (it cannot be
connected to a live network).
Response/Messages
After the command has been issued, the following line is printed:
DEC CNCTR: Connector:..................Running --->
If all parts of the test are completed correctly, then the test passes:
DEC CNCTR: Connector:...............Running ---> PASSED
If any part of the test fails, then the display appears as follows:
DEC CNCTR: Connector:....................Running ---> FAILED
DEC/CNCTR Test Failure Data:
(error message)
Refer to the section DEC Error Messages for a list of the error messages
and their meaning.
You can use the CF command to select the port to be tested (whether AUI
or TP). The following example uses the CF command to select port 1 (the
TP port), skipping port 0 (the AUI port).
Example:
PPCx-Diag>CF DEC
DEC Configuration Data:
Port Select =00000000 ? 1