Technical data
2-12 Computer Group Literature Center Web Site
Diagnostic Utilities
2
PPC1-Diag>mask ram adr
Update Non-Volatile RAM (Y/N)? y
RAM/ADR
PPC1-Diag>mask
RAM/ADR
PPC1-Diag>
NV - Non-Verbose Mode
Upon detecting an error, the tests display a substantial amount of data. To
avoid the necessity of watching the scrolling display, you can choose a
mode that suppresses all messages except test name and
PASSED or FAILED.
This mode is called non-verbose and you can invoke it prior to calling a
command by entering NV.
Example:
PPC1-Diag>nv;uart lpbke
UART LPBKE:External Loopback .......Running --> FAILED
PPC1-Diag>
NV causes the monitor to run the UART external loopback test, but show
only the name of the test and the results (pass/fail).
PPC1-Diag>uart lpbke
UART LPBKE:External Loopback .......Running --> FAILED
UART/LPBKE Test Failure Data:
RTS loopback to CTS or RI Failed: COM2
PPC1-Diag>
Without nv, the failure data is displayed.
SD - Switch Directories
The SD command allows you to switch back and forth between PPCBug’s
diagnostic directory (the prompt reads
PPC
x
-Diag>) and the debug
directory (the prompt reads
PPC