Technical data

Utilities
http://www.motorola.com/computer/literature 2-3
2
CEM - Clear Error Messages
This command allows you to clear the internal error message buffer of the
diagnostic monitor manually.
Example:
PPC
x
-Diag>cem
(error message buffer is cleared)
PPC
x
-Diag>
CF - Test Group Configuration Parameters Editor
The CF parameters control the operation of all tests in a test group.
For example, the RAM test group has parameters such as starting address,
ending address, parity enable, etc. At the time of initial execution of the
diagnostic monitor, the default configuration parameters are copied from
the firmware into the debugger work page. Here you can modify the
configuration parameters via the CF command.
When you invoke the CF command, you are interactively prompted with
a brief parameter description and the current value of the parameter. You
may enter a new value for that parameter, or a RETURN to accept the
current value and proceed to the next configuration parameter. To
discontinue the interactive process, enter a period (
. ) followed by
RETURN.
You may specify one or more test groups as argument(s) immediately
following the CF command on the command line. If no arguments follow
the CF command, the parameters for all test groups are presented so you
may change them if you wish.
Examples: