Diagnostic Utilities
2
Notes
You may enter command names in either uppercase or
lowercase.
Terminate all command lines by pressing the
RETURN key.
AEM - Append Error Messages Mode
The AEM command allows you to accumulate error messages in the
internal error message buffer of the diagnostic monitor.
This command sets the internal append error messages flag of the
diagnostic monitor. The default of the internal append error messages flag
is clear. The internal flag is not set until it is encountered in the command
line by the diagnostic monitor.
The contents of the buffer can be displayed with the DEM command.
When the internal append error messages flag is not set or is cleared with
CEM, the diagnostic error message buffer is erased (cleared of all
character data) before each test is executed.
The duration of this command is for the life of the command line being
parsed by the diagnostic monitor.
Example:
PPC
x
-Diag>aem; ram ref
RAM REF: Memory Refresh Test............ Running ---> FAILED
(error message written to error message buffer)
PPC
x
-Diag>