Technical data

Z8536 - Counter/Timer Tests
http://www.motorola.com/computer/literature 3-153
3
REG - Register
Command Input
PPCx-Diag>z8536 reg
Description
This test verifies that all of the Z8536 registers can be written and read.
Data patterns verify that every read/write bit can be modified.
Response/Messages
After the command has been issued, the following line is printed:
Z8536 REG: Register.........................Running --->
If all parts of the test are completed correctly, then the test passes:
Z8536 REG: Register...................Running ---> PASSED
If any failures occur, the following is displayed (more descriptive text then
follows):
Z8536 REG: Register..................Running ---> FAILED
Z8536/REG Test Failure Data:
(error message)
If the test fails because the pattern written doesn’t match the data read back
from the Z8536 register, the following message is displayed:
Register xxx Miscompare Error:Address =____,Expected =_,Actual =_