VME3- Universe VME to PCI Bridge Tests
http://www.motorola.com/computer/literature 3-145
3
Entering VME3 without parameters causes all VME3 tests to run in the
order shown in the table below, except as noted.
To run an individual test, add that test name to the VME3 command. The
individual tests are described in alphabetical order on the following pages.
The PPCBUG Diagnostics engine includes a test init function, which is run
prior to each of the tests in the test group. For the Universe diagnostics,
several things will be tested during test init.
The init phase testing verifies that there is agreement between the board’s
Base Module Feature Register (BMFR) and the actual installation of the
board’s Universe chip. If the VME Present bit in the BMFR indicates the
Universe is not installed, all post-init phase Universe testing will be
bypassed. Whether this is an error condition or not depends on the
following sets of conditions. In order to establish whether the Universe is
actually installed, the Universe’s PCI Configuration Space Vendor ID
value (at offset 2) is read. If the Vendor ID indicates that the Universe is
installed, but the VME Present bit indicates it should not be, an error will
be logged and the currently-running test will exit. If the Vendor ID cannot
be read and the VME Present bit indicates the device should be installed,
an error will be logged and the currently-running test will exit.
There are currently no active CF parameters for the Universe Tests.
Table 3-25. VME3 Test Group
Name Description
REGR Register Read
REGW Register walking bits (write/read)