Technical data
3-124 Computer Group Literature Center Web Site
Test Descriptions
3
ELPBCK - External Loopback
Command Input
PPCx-Diag>SCC ELPBCK
Description
This test transmits 256 characters at 38400 baud. The data is received and
compared. If any protocol errors are created or the data is not correct when
received, the test fails.
This test does require an external loopback connector to be installed. For
this test, the following connections need to be made in the loopback
connector:
Response/Messages
After the command has been issued, the following line is printed:
SCC ELPBCK: External Loopback............ Running --->
If all parts of the test are completed correctly, then the test passes:
SCC ELPBCK: External Loopback.......Running ---> PASSED
If any part of the test fails, then the display appears as follows:
SCC ELPBCK: External Loopback.......Running ---> FAILED
SCC/ELPBCK Test Failure Data:
(error message)
Refer to the section SCC Error Messages for a list of the error messages
and their meaning.
TxD connected to RxD