Technical data
SCC - Serial Communication Controller (Z85230) Tests
http://www.motorola.com/computer/literature 3-119
3
Example:
PPC1-Diag>CF SCC
SCC Memory Space Base Address =80000840?RETURN
Internal-Loopback/Baud-Rates Port Mask =00000003? 2
(Bit 0 selects port 0, Bit 1 selects port 1; see note below.)
External-Loopback/Modem-Control Port Mask=00000003?
The first parameter is the base address space for the Z85230 devices. This
is preset for the PowerPC family of boards and should not be changed.
The next two parameters are the port selection masks. These masks are
used during testing to identify which ports are to be tested. The default is
to test every port. The Internal-Loopback/Baud-Rates Port Mask is used
for the BAUDS and ILPBCK test suites. The External-Loopback/Modem-
Control Port Mask is only used for the ELPBCK and MDMC test suites.