Technical data

RAM - Local RAM Tests
http://www.motorola.com/computer/literature 3-107
3
REF - Memory Refresh Testing
Command Input
PPCx-Diag>RAM REF
Description
The memory range and address increment is specified by the RAM test
directory configuration parameters. (Refer to
CF - Test Group Configuration
Parameters Editor
in Chapter 2.)
First, the real time clock is checked to see if it is functioning properly.
Second, each memory location to be tested has the data portion verified by
writing/verifying all zeros, and all ones. Next a data pattern is written to
the test location. After all the data patterns are filled for all test locations,
a refresh wait cycle is executed. After the wait cycle, the data is read, and
if the previously entered data pattern does not match the data pattern read
in, a failure occurs. If the data patterns match, then the test is passed.
Response/Messages
After the command has been issued, the following line is printed:
RAM REF: Memory Refresh Test..............Running --->
If all parts of the test are completed correctly, then the test passes:
RAM REF: Memory Refresh Test........Running ---> PASSED
If any part of the test fails, then the display appears as follows:
RAM REF: Memory Refresh Test........Running ---> FAILED
RAM/REF Test Failure Data:
(error message)
Here
(error message)
is one of the following:
If the real time clock is not functioning properly, one of the following is
printed:
RTC is stopped, invoke SET command.
Or: