User`s guide
To connect the termination adapters
1 Align the key on the male end of the termination adapter with the slot
on the connector of one of the logic analyzer cables (not shown), and
push the termination adapter into the connector.
2 Connect the female end of the termination adapter to the
preprocessor interface as shown in the figure below. For connectors
without a guide slot, orient the adapter the same as for other
connectors.
The logic analyzer probes must be terminated for correct operation. On the
preprocessor interface, there are nine connectors.
•
P4 only has a terminated connector (2x20 pins).
•
P2, P5, P6 and P7 only have nonterminated connectors (2x10 pins).
•
P1 and P3 have both terminated and nonterminated connectors.
The terminated connectors may be connected directly to the logic analyzer.
The nonterminated connectors must be probed by using either the General
Purpose probes (shipped with the logic analyzer) or the 100 kOhm
Termination Adapters (HP part number 01650-63203).
Connecting the Termination Adapter
Figure 4
Setting Up the Preprocessor Interface
To connect the termination adapters
1–24 MC68306 Preprocessor