Specifications
Table Of Contents
- MC3000
- Revision History
- Contents
- About This Guide
- Getting Started
- Introduction
- Unpacking the Mobile Computer
- Accessories
- Parts
- Mobile Computer Startup
- Battery Charging
- Spare Battery Charging
- Stylus
- Starting the Mobile Computer
- Resetting the Mobile Computer
- Waking the Mobile Computer
- Main Battery Removal
- Strap/Door Assembly Removal and Replacement
- Strap/Door Assembly Removal and Replacement (MC3090-G)
- File System Directory Structure
- Flash Storage
- Launching Applications
- Accessories
- ActiveSync
- Software Installation on Development PC
- Software Installation on Mobile Computer
- Creating/Loading Hex Images
- Wireless Applications
- AirBEAM Smart
- Rapid Deployment Client
- Maintenance & Troubleshooting
- Technical Specifications
- Glossary
- Index
- Tell Us What You Think...

MC3000 Integrator Guide10-8
Four Slot Spare Battery Charger
UBC Adapter
Table 10-5. Troubleshooting the Four Slot Spare Battery Charger
Problem Cause Solution
Spare Battery Charging LED
does not light when spare
battery is inserted.
Spare battery is not correctly
seated.
Remove and re-insert the spare battery into the charging slot, ensuring it is correctly
seated.
Battery not charging. Charger is not receiving power. Ensure the power cable is connected securely to both the charger and to AC power.
Battery is not correctly seated. Remove and re-insert the battery into the charger, ensuring it is correctly seated.
Battery was removed from charger
or charger was unplugged from AC
power too soon.
Ensure charger is receiving power. Ensure the battery is seated correctly. If a battery is
fully depleted, it can take up to four hours to fully recharge a Standard Battery and it can
take up to six hours to fully recharge an Extended Life Battery.
Battery is faulty. Verify that other batteries charge properly. If so, replace the faulty battery.
Table 10-6. Troubleshooting the UBC Adapter
Problem Cause Solution
Spare battery Charging LED
does not light when spare
battery is inserted.
Spare battery is not correctly
seated.
Remove and re-insert the spare battery into the charging slot, ensuring it is correctly
seated.
Battery not charging. Charger is not receiving power. Ensure the power cable is connected securely to both the charger and to AC power.
Spare battery is not correctly
seated.
Remove and re-insert the spare battery into the charger, ensuring it is correctly seated.
Battery was removed from charger
or charger was unplugged from AC
power too soon.
Ensure charger is receiving power. Ensure the battery is seated correctly. If a battery is
fully depleted, it can take up to four hours to fully recharge a Standard Battery and it can
take up to six hours to fully recharge an Extended Life Battery.
Battery is faulty. Verify that other batteries charge properly. If so, replace the faulty battery.