Specifications
Table Of Contents
- MC3000
- Revision History
- Contents
- About This Guide
- Getting Started
- Introduction
- Unpacking the Mobile Computer
- Accessories
- Parts
- Mobile Computer Startup
- Battery Charging
- Spare Battery Charging
- Stylus
- Starting the Mobile Computer
- Resetting the Mobile Computer
- Waking the Mobile Computer
- Main Battery Removal
- Strap/Door Assembly Removal and Replacement
- Strap/Door Assembly Removal and Replacement (MC3090-G)
- File System Directory Structure
- Flash Storage
- Launching Applications
- Accessories
- ActiveSync
- Software Installation on Development PC
- Software Installation on Mobile Computer
- Creating/Loading Hex Images
- Wireless Applications
- AirBEAM Smart
- Rapid Deployment Client
- Maintenance & Troubleshooting
- Technical Specifications
- Glossary
- Index
- Tell Us What You Think...

MC3000 Integrator Guide6-16
Insufficient data available to
complete record
-21 A Symbol HEX file download was attempted but the HEX file is invalid. Ensure the file is in Symbol HEX
file format.
Invalid Symbol HEX file -23 A Symbol HEX file download was attempted but the HEX file is invalid. Ensure the file is in Symbol HEX
file format.
Unrecognized or unsupported HEX
record
-24 The Symbol HEX file being downloaded contains an invalid or unrecognized HEX record. Ensure the file
is in proper Symbol HEX file format.
Invalid data in HEX file -25 The Symbol HEX file being downloaded contains invalid data. Ensure the file is in proper Symbol HEX
file format with valid HEX data.
Exceeded max size -26 The download file is too large to fit into the space allocated for it. Either make the file smaller or increase
the space allocated for it by altering the partition table.
Partition is not valid on this device -27 The downloaded file specifies a partition entry that does not exist on the device. Only download files
that are valid for this device, or change the partition table so that the new file is valid on the device.
Wrong destination code -28 A specific partition was chosen from the IPL main menu (not Auto Select) but the file selected for
download was for another partition. Ensure that the partition selected from the IPL main menu matches
the file selected for download.
File type does not support IPL Auto
Select
-29 Monitor, Power Micro and Partition Table cannot be loaded with Auto Select. Select the appropriate
area, and try again.
Non-contiguous record found -30 A Symbol HEX file download was attempted but the HEX file is invalid. Ensure the file is in Symbol HEX
file format.
Timed Out - No data -31 IPL was waiting for data from the source device but timed out before receiving any. Check the source
device connectivity and retry.
Fail: Buffer Overrun -32 The serial port device could not keep up with incoming data. Retry the serial download with a lower baud
rate.
Partition Table not Valid -33 The size of flash memory is different than that described in the partition table. Retry the download with
the correct partition table file.
Invalid file format -34 The file format is invalid. Only Symbol HEX files are supported by IPL.
Table 6-4. IPL Errors (Continued)
Error Text Error Number Probable Cause