Specifications
Application Deployment 9 - 17
Transmission checksum 
error
-11 An error occurred during transmission from the source device 
(either radio card or Serial port) and the checksum check failed. 
Check source device connectivity and retry.
Readback checksum 
error
-12 A checksum, generated from reading back data that was written to 
the destination device, was incorrect. An error during transmission 
or a write error to the destination device could cause this.
There is no more heap 
space available
-14 There is no more heap space available for the download procedure. 
Restart IPL and retry the download. If the failure persists, contact 
service with details of what is being downloaded.
Insufficient data 
available to complete 
record
-21 A Symbol HEX file download was attempted but the HEX file is 
invalid. Ensure the file is in Symbol HEX file format.
Invalid Symbol HEX file -23 A Symbol HEX file download was attempted but the HEX file is 
invalid. Ensure the file is in Symbol HEX file format.
Unrecognized or 
unsupported HEX 
record
-24 The Symbol HEX file being downloaded contains an invalid or 
unrecognized HEX record. Ensure the file is in proper Symbol HEX 
file format.
Invalid data in HEX file -25 The Symbol HEX file being downloaded contains invalid data. 
Ensure the file is in proper Symbol HEX file format with valid HEX 
data.
Exceeded max size -26 The download file is too large to fit into the space allocated for it. 
Either make the file smaller or increase the space allocated for it by 
altering the partition table.
Partition is not valid on 
this device
-27 The downloaded file specifies a partition entry that does not exist on 
the device. Only download files that are valid for this device, or 
change the partition table so that the new file is valid on the device.
Wrong destination code -28 A specific partition was chosen from the Main Menu (not Auto 
Select) but the file selected for download was for another partition. 
Ensure that the partition selected from the Main Menu matches the 
file selected for download.
File type does not 
support IPL Auto Select
-29 Monitor, Power Micro and Partition Table cannot be loaded with 
Auto Select. Select the appropriate area, and try again.
Non-contiguous record 
found
-30 A Symbol HEX file download was attempted but the HEX file is 
invalid. Ensure the file is in Symbol HEX file format.
Timed Out - No data -31 IPL was waiting for data from the source device but timed out before 
receiving any. Check the source device connectivity and retry.
Table 9-4
IPL Errors (Continued)
Error Text
Error
Number
Probable Cause