Specifications
9 - 14 MC17/MC17A/MC17T/MC17U Product Reference Guide
Figure 9-12
Load Terminal Window - Serial and Ethernet Tabs
14. Select the Image Files To Load.
15. In the Comm Port drop-down list, select USB: Symbol Device.
16. Click Download to begin the operation.
17. During download, the Downloading screen on mobile computer displays the Device Status and a
progress bar.
18. When complete, Device Status displays Result was: Success!, or in the case of an error, the cause of
the error.
19. On completion, press ENTER to return to the IPL menu to select the next partition to download.
20. To exit IPL, select the System Reset item from the IPL menu (see Figure 9-7 on page 9-10).
TCM Error Messages
TCM validates the cells in the partition table when the Execute button is clicked. Cells highlighted in red contain
an error. Partition loading is disabled until all errors are corrected.
Table 9-3
TCM Error Messages
Error Description/Solution
Failed to build images:
flash file system DLL not
loaded!
TCM could not load the DLL required to build images for the targeting flash file
system. Reinstall TCM or recover the DLL.
Failure finding directory
xxx
Building process failed because directory xxx was not found.
Failure creating volume Building process failed because a certain disk volume could not be created.
Failure adding system file
to image
Build process failed because TCM failed to add a certain system file to the disk
image.
INVALID PATH The path for the image file to build is not valid.
Nothing Selected To Build In the Config Build window, no item is selected to build.
Illegal ESS ID In the Build ESSID Partition window, no ESS ID was entered or the ESS ID entered
was illegal.