Technical data
Hardware and Firmware
Hardware Descriptions
DRM043/D — Rev 0 Designer Reference Manual
MOTOROLA Hardware and Firmware 11
If the battery is built in with a NTC, the NTC Z1 on the demo board can
be removed.
2.2.4 Charging status
PTA3 is used to control the on-off of two LEDs to indicate different
charging status( see Table 2-1).
To turn on both LEDs, PTA3 is set as input. When set to output high, it
will turn on the Green LED. When set as output low, it will turn on the
Red LED.
2.2.5 In-Circuit-Programming
J2 contains the signals for the MCU68HC908QT2 to enter monitor mode
for ICP. The ICP requires connecting J2 with a cable to the ICP adaptor
board, which is plugged-into the M68HC08 Serial Programmer
(M68SPGRM08) (see Figure 2-2). The signals from the J2 are Vdd, Vss,
Vtst and OSC1 and PA0. Beside these signals, enter monitor mode also
required PTA1 pull-up and PTA4 pull-down. When ICP, the jumper J3
must be opened to disconnect the filter cap, 0.1uF at PTA0/AD0.
The programming software is the PROG08SZ.exe from P&E. Select
Class I for Target Hardware Type. The baud rate is 4800bps. The ICP
support erase, programming and verify the firmware in the MCU.
Table 2-1. Charging Status
RED GREEN
Fast Charge in progress On Off
Battery is fully charged Off On
Battery is not connected On On
Fault condition occurred --Flashing--
Frees
cale Semiconductor,
I
Freescale Semiconductor, Inc.
For More Information On This Product,
Go to: www.freescale.com
nc...