User manual
Table Of Contents
- COVER
- TABLE OF CONTENTS
- CHAPTER 1 GENERAL INFORMATION
- CHAPTER 2 DEBUG MONITOR DESCRIPTION
- CHAPTER 3 DEBUG MONITOR COMMANDS
- CHAPTER 4 ASSEMBLER/DISASSEMBLER
- CHAPTER 5 SYSTEM CALLS
- CHAPTER 6 DIAGNOSTIC FIRMWARE GUIDE
- APPENDIX A S-RECORD INFORMATION
- APPENDIX B SELF-TEST ERROR MESSAGES
- APPENDIX C USER CUSTOMIZATION
- LIST OF FIGURES
- LIST OF TABLES
- Table 2-1. Debugger Address Parameter Format
- Table 2-2. CPU32Bug Exception Vectors
- Table 3-1. Debug Monitor Commands
- Table 4-1. CPU32Bug Assembler Addressing Modes
- Table 5-1. CPU32Bug System Call Routines
- Table 6-1. MCU CPU Diagnostic Tests
- Table 6-2. Memory Diagnostic Tests
- Table B-1. Self-Test Error Messages
- Table C-1. CPU32Bug Customization Area
- Table C-2. MCU SCI Communication Formats
- Table C-3. Rev. A Chip Selection Summary
- Table C-4. Rev. B Chip Selection Summary
- Table C-5. BCC Rev. C Chip Selection Summary
- Table C-6. PFB Rev. C Compatibility
- CHAPTER 1 GENERAL INFORMATION
- CHAPTER 2 DEBUG MONITOR DESCRIPTION
- CHAPTER 3 DEBUG MONITOR COMMANDS
- 3.1 INTRODUCTION
- 3.2 BLOCK OF MEMORY COMPARE
- 3.3 BLOCK OF MEMORY FILL
- 3.4 BLOCK OF MEMORY MOVE
- 3.5 BREAKPOINT INSERT/DELETE
- 3.6 BLOCK OF MEMORY SEARCH
- 3.7 BLOCK OF MEMORY VERIFY
- 3.8 DATA CONVERSION
- 3.9 DUMP S-RECORDS
- 3.10 GO DIRECT (IGNORE BREAKPOINTS)
- 3.11 GO TO NEXT INSTRUCTION
- 3.12 GO EXECUTE USER PROGRAM
- 3.13 GO TO TEMPORARY BREAKPOINT
- 3.14 HELP
- 3.15 LOAD S-RECORDS FROM HOST
- 3.16 MACRO DEFINE/DISPLAY/DELETE
- 3.17 MACRO EDIT
- 3.18 MACRO EXPANSION LISTING ENABLE/DISABLE
- 3.19 MEMORY DISPLAY
- 3.20 MEMORY MODIFY
- 3.21 MEMORY SET
- 3.22 OFFSET REGISTERS DISPLAY/MODIFY
- 3.23 PRINTER ATTACH/DETACH
- 3.24 PORT FORMAT
- 3.25 REGISTER DISPLAY
- 3.26 COLD/WARM RESET
- 3.27 REGISTER MODIFY
- 3.28 REGISTER SET
- 3.29 SWITCH DIRECTORIES
- 3.30 TRACE
- 3.31 TRACE ON CHANGE OF CONTROL FLOW
- 3.32 TRANSPARENT MODE
- 3.33 TRACE TO TEMPORARY BREAKPOINT
- 3.34 VERIFY S-RECORDS AGAINST MEMORY
- CHAPTER 4 ASSEMBLER/DISASSEMBLER
- CHAPTER 5 SYSTEM CALLS
- 5.1 INTRODUCTION
- 5.2 SYSTEM CALL ROUTINES
- 5.2.1 Calculate BCD Equivalent Specified Binary Number
- 5.2.2 Parse Value, Assign to Variable
- 5.2.3 Check for Break
- 5.2.4 Timer Delay Function
- 5.2.5 Unsigned 32 x 32 Bit Divide
- 5.2.6 Erase Line
- 5.2.7 Input Character Routine
- 5.2.8 Input Line Routine
- 5.2.9 Input Serial Port Status
- 5.2.10 Unsigned 32 x 32 Bit Multiply
- 5.2.11 Output Character Routine
- 5.2.12 Output String Using Pointers
- 5.2.13 Print Carriage Return and Line Feed
- 5.2.14 Read Line to Fixed-Length Buffer
- 5.2.15 Read String Into Variable-Length Buffer
- 5.2.16 Return to CPU32Bug
- 5.2.17 Send Break
- 5.2.18 Compare Two Strings
- 5.2.19 Timer Initialization
- 5.2.20 Read Timer
- 5.2.21 Start Timer at T=0
- 5.2.22 Output String with Data
- 5.2.23 Output String Using Character Count
- CHAPTER 6 DIAGNOSTIC FIRMWARE GUIDE
- 6.1 INTRODUCTION
- 6.2 DIAGNOSTIC MONITOR
- 6.2.1 Monitor Start-Up
- 6.2.2 Command Entry and Directories
- 6.2.3 Help (HE)
- 6.2.4 Self Test (ST)
- 6.2.5 Switch Directories (SD)
- 6.2.6 Loop-On-Error Mode (LE)
- 6.2.7 Stop-On-Error Mode (SE)
- 6.2.8 Loop-Continue Mode (LC)
- 6.2.9 Non-Verbose Mode (NV)
- 6.2.10 Display Error Counters (DE)
- 6.2.11 Clear (Zero) Error Counters (ZE)
- 6.2.12 Display Pass Count (DP)
- 6.2.13 Zero Pass Count (ZP)
- 6.3 UTILITIES
- 6.4 CPU TESTS FOR THE MCU
- 6.5 MEMORY TESTS (MT)
- 6.6 BUS ERROR TEST
- APPENDIX A S-RECORD INFORMATION
- APPENDIX B SELF-TEST ERROR MESSAGES
- APPENDIX C USER CUSTOMIZATION

SYSTEM CALLS
M68CPU32BUG/D REV 1 5-4
.BINDEC Calculate BCD Equivalent Specified Binary Number .BINDEC
5.2.1 Calculate BCD Equivalent Specified Binary Number
SYSCALL .BINDEC
TRAP CODE: $0064
This function takes a 32-bit unsigned binary number and changes it to its equivalent BCD
(Binary Coded Decimal Number).
Entry Conditions:
SP ==> Argument: Hex number <long>
Space for result <2 long>
Exit Conditions:
SP ==> Decimal number (2 Most Significant Digits) <long>
(8 Most Significant Digits) <long>
EXAMPLE
SUBQ.L #8,A7
Allocate space for result
MOVE.L D0,-(A7)
Load hex number
SYSCALL .BINDEC
Call .BINDEC
MOVEM.L (A7)+,D1/D2
Load result into D1/D2
SYSTEM CALLS
M68CPU32BUG/D REV 1 5-5
.CHANGEV Parse Value, Assign to Variable .CHANGEV
5.2.2 Parse Value, Assign to Variable
SYSCALL .CHANGEV
TRAP CODE: $0067
Parse a value in the user specified buffer. If the user specified buffer is empty, the user is
prompted for a new value, otherwise update the integer offset into the buffer to skip the value.
The new value is displayed and assigned to the variable unless the user’s input is an empty string.
Entry Conditions:
SP ==> Address of 32-bit offset into user’s buffer
Address of user’s buffer (pointer/count format string)
Address of 32-bit integer variable to change
Address of string to use in prompting and displaying value
Exit Conditions:
SP ==> Top of stack
EXAMPLE
PROMPT DC.B $14,’COUNT = |10,8|’
GETCOUNT PEA PROMPT(PC)
Point to prompt string
PEA COUNT Point to variable to change
PEA BUFFER Point to buffer
PEA POINT Point to offset into buffer
SYSCALL .CHANGEV Make the system call
RTS COUNT changed, return
Fr
eescale S
emiconduct
or
, I
Freescale Semiconductor, Inc.
For More Information On This Product,
Go to: www.freescale.com
nc...