Specifications
VP ONCORE COMMAND REFERENCE
POSITION-HOLD MODE SELECT (@@At)
Motorola Binary Format
Input Command • Request current Position-Hold mode:
@@AtxC<CR><LF>
x - 1 out of range byte $ff
C - checksum
Message length: 8 bytes
• Change current Position-Hold Mode:
@@AtmC<CR><LF>
m - mode 0 = disabled
1 = enabled
C - checksum
Message length: 8 bytes
Response Message • (to either command)
@@AtmC<CR><LF>
m - mode 0 = disabled
1 = enabled
C - checksum
Message length: 8 bytes
57 Synergy Systems, LLC 05OCT01