Specifications
VP ONCORE COMMAND REFERENCE
DATE (@@Ac)
Motorola Binary Format
Input Command
•
•
•
Request Current Date:
@@AcxxxxC<CR><LF>
xxxx - 4 out of range bytes $ffffffff
C - checksum
Message length: 11 bytes
Change current Date:
@@AcmdyyC<CR><LF>
m - month 1 .. 12
d - day 1 .. 31
yy - year 1980 .. 2077
C - checksum
Message length: 11 bytes
Response Message
To either command:
@@AcmdyyC<CR><LF>
m – month 1 .. 12
d - day 1 .. 31
yy - year 1980 .. 2077
C - checksum
Message length: 11 bytes
14 Synergy Systems, LLC 05OCT01