User`s guide
Chapter 5 - I/O Commands
TIME RAIM ALARM MESSAGE (@@Gf)
Applicability: M12+ timing receivers
This message allows the user to enter the Time RAIM alarm limit in multiples of 100 ns, or to
query the receiver for the current setting. The default alarm limit is 1000 ns.
Default value: 1000 ns
This command was part of the @@En message used on 8 channel UT+ and VP timing receivers.
Motorola GPS Products - M12+ User's Guide Revision 6.X 09FEB05