User`s guide
Chapter 5 - I/O Commands
POSITION LOCK SELECT MESSAGE (@@AS)
Motorola Binary Format
Query current Position Lock Select Status:
@@ASxC<CR><LF>
where:
x = 1 out of range hex byte: 0xFF
C = 0xED
Message length: 8 bytes
Complete hex string to query current Position Lock Select Status:
0x40 40 41 53 FF ED 0D 0A
Change current Position Lock Select Status:
@@ASeC<CR><LF>
where:
e = selection 0x00 = Disabled
0x01 = Enabled
C = checksum
Message length: 8 bytes
Response to either command:
@@ASeC<CR><LF>
where:
e = selection 0x00 = Disabled
0x01 = Enabled
C = checksum
Message length: 8 bytes
Motorola GPS Products - M12+ User's Guide Revision 6.X 09FEB05