Sewing Machine User Manual
HE-8000
5. OPERATION
33
5-4. Program setting method
5-4-1. Program initialization condition
The parameters and memory switches for program numbers 1 to 90 are all set to their default values.
5-4-2. Parameter table
• The parameter values can be stored independently for each program.
• The allowable setting range for some parameters may vary from the range specified, depending on the
settings of other parameters.
• The number of stitches which can be sewn may vary depending on settings for parameters such as zigzag
width and feed length.
• The zigzag width ratio cannot be set when the rear tack pattern is set to an eyelet pattern.
• If all underlays have been set, the order of sewing is underlays sewn together, then saw-shape underlays
and then rectangle underlays.
* The cutter operating distance may become smaller depending on the settings for parameter No. 2 (Length
of knife) and parameter No. 3 (zigzag stitch length [multi-working knife]), so in such cases the speed will
be reduced automatically.
No. Setting items Setting range Unit Default
00 Sewing speed (zigzag part) 1,000 – 4,000 rpm 100 3,600
01 Buttonhole/Straight bar tack
0: 1: 2: 3: 4:
0: Buttonhole (free)
1: Buttonhole (rectangle)
2: Buttonhole (radial)
3: Buttonhole (round)
4: Bar tack
1
02 Length of knife
4.0 - 32.0 mm
However, when panel DIP
switches B-3, B-4 or B-5
are at OFF, OFF and ON
respectively when initializa-
tion is carried out, the initial
value will be set to 6.0.
0.1 13.0
(6.0)
03 Zigzag stitch length (multi-working knife)
OFF: Single working knife
4.0 - 69.0 mm
However, the setting range
will be limited by the work
clamp size setting value
which has been set by the
B panel DIP switches.
0.1 OFF
04 Zigzag pitch 0.10 - 2.00 mm 0.025 0.350
1437Q
1438Q
1439Q
1440Q