Specifications

Network Planning A-6
Capacity Tables
Table A-8 Packet Duplicator Limitation Guidelines
Table A-9 Metro Packet Switch Limitation Guidelines
Table A-10 Mobile Data Gateway Limitation Guidelines
Table A-11 EBTS Access Control Gateway Limitation Guidelines
Subsystem Users Sites Limiters BRs Comment
APD N/A 1000 (250/port) 2000 simultaneous calls 500 call/port
*Erlangs/subscriber (user) can not exceed Calls/Port limitation
Subsystem Users Sites Limiters BRs Comment
MPS (lgx 32)
MPS (bpx)
45
N/A
75
200/SM
N/A
PD Port capacity
6 /EBTS site
75 sites @ 4DS0s/site (up to 6BRs)
Icons=1000
Max./PVCs=16000 w npm64B cards
SwitchModules = PD port
Max No. of Cards - 32
Max. of 256mbps bandwidth
250 sites @ 6DS0s/site
16 MSX per BPX shelf
Max. BPX b/w = 9.6Gb
Subsystem Users Sites Limiters BRs Comment
MDG
(SR 8.0)
15,000 500 10 call /PCH N/A
10 Packet Data calls
Maximum of 4 Frame Relay V.34 connections
1 Ethernet 10BaseT
MDG
(SR 9.1)
65,000 500
411 kbps I/B
311 kbps O/B
N/A
Minimum of 2 Frame Relay V.35 connections
Maximum of 4 Frame Relay V.35 connections
1 Ethernet 10BaseT
I/B and O/B Call Model is based on 5 sessions/user in Busy Hr.
Subsystem Users Sites Limiters BRs Comment
ACG (sr7.0)
ACG (sr 9.1)
N/A 1 Logical
12:1
DCCH
holdbacks
20 - omni
24 - 3-sector
12 with VME EBTS
(sr7.0)
(sr 9.1)
Busy Queue = 35
12 BRs× PCCH SCCH+()–127
BRs 6×()3()BusyQueue+176=