Specifications
A-5 Network Planning
Capacity Tables
Table A-5 Base Site Controller - Control Processor Limitation Guidelines
Table A-6 Base Site Controller - Transcoder Limitation Guidelines
Table A-7 Dispatch Application Processor Limitation Guidelines
Subsystem Users Sites Limiters BRs Comment
BSC-CP N/A 33 N/A
792
(Typically < 400)
Max Erlangs - 1200 (Typically < 400)
Max. No. of BRs = Maxsites*MaxBRs/site (33*24)
Max of 7 loads per LCF GPROC
1 MTL = 7 Loads
1 Site = 1 load consisting of 2 RSLs (Mobis and SNMP)
1 XBL = 1 load
BSC-ECP N/A 80 N/A
1600
(Typically <
1100)
Max of 1240 Erlangs / BSC-ECP (Typically < 800)
Max of 12 loads per LCF GPROC
1 MTL = 12 Loads
1 Site = 1 load consisting of 2 RSLs (Mobis and SNMP)
1 XBL = 1 load
Subsystem Users Sites Limiters BRs Comment
BSC-XCDR N/A N/A
1008 TDMA Timeslots
Number of cirucits
N/A
Max. No. of Base Radios per XCDR is not applicable
Max. Erlangs - 1240 (Typically < 300)
Max of 1 active KSW
EXCDR N/A N/A
4032 TDMA Timeslots
Number of Circuits
Max of 4 active KSW (Max of 4032 TDM timeslots)
Max of 1320 CICS (Typically < 900)
Max of 1240 Erlangs (Typically < 800)
Subsystem Users Sites Limiters BRs Comment
T-DAP - 90 90,000 1,000
65% CPU Usage* N/A
125 Sites/SBE. Maximum No. of SBEs = 12
83 Sites/SBE Maximum No. of SBEs = 16
50 Sites/SBE Maximum No. of SBEs = 24
SBE limits are based on 4 SM configuration
T-DAP - 180 180,000 1,000
*CPU Limits based on profile and growth rate