Operating instructions

GX2-PSAC10D-R Installation and Operation Manual
Appendix A
Specifications
Specifications for the GX2-PSAC10D-R are valid over the given operating temperature range. Refer
to the current Motorola BCS product catalog for additional information not provided in this section.
Input Power
AC input voltage
105 Vrms to 264 Vrms
AC current
At 115 V
At 230 V
4.0 amps rms maximum with full load
2.0 amps rms maximum with full load
Power consumption
420 watts maximum with full load
Efficiency
68% at maximum load
Fusing
Two 10 amp slow blow at power input connector
Output Power
Output voltage
+5.1 VDC range
+12 VDC range
+3.7 VDC range
5.05 to 5.15 VDC nominal with maximum load at +25°C
11.88 to 12.12 VDC nominal with maximum load at +25°C
3.66 to 3.75 VDC nominal with maximum load at +25°C
Output current
+5.1 VDC range
+12 VDC range
+3.7 VDC range
Maximum total output
power
17.9 amps maximum with maximum load at +25°C
16.1 amps maximum with maximum load at +25°C
19.2 amps maximum with maximum load at +25°C
300 Watts
Physical Properties
Dimensions
2.2” H x 7.7” W x 11.7” D (5.6 cm x 19.6 cm x 29.7 cm)
Weight
8.0 lb (3.6 kg)
Mounting
GX2-HSG*
Environmental
Operating temperature
range
-20°C to +60°C (-4° to +140°F)
Storage temperature
range
-40°C to +85°C (-40° to +186°F)