GT10/GT30 4.12 Connecting with a PLC by Omron Corp.
66
SYSMAC C series (direct connection to CPU)
CPU *1 Usable cables GT series
C200HS
SRM1–C02
CQM1–CPU11
CQM1–CPU42
CPM1–20CDR–A
CQM1H–CPU21 *2
Isolation cable by Omron
Corporation
CQM1–CIF01
GT10/GT30
*1 This is connected to the peripheral port.
*2 The CS1W–CN114 cable by Omron Corporation is required.
CAUTION
Please be aware that, because only one peripheral port is provided
with the CQM1–CPU11, it cannot be used at the same time as a PLC.
SYSMAC α series (using link interface)
CPU Link I/F Wiring diagram GT series
C200HX–
CPU85–Z
CPU64
CPU44
C200HE–
CPU42
C200HG–
CPU63
CPU43
C200HW–COM06
D–sub 9–pin on Omron PLC side
SD SD
RD RD
RS RS
CS CS
GND GND
GT main unit side
Pin no.
Abbreviation
1FG
2SD
3RD
4RS
5CS
Pin no.
Abbreviation
6
7
GT10/GT30
C200HE–
CPU42–Z
RS232C port on
CPU unit
7
8
9SG
C200HX–
CPU64–Z
C200–LK201–V1
1FG
2SD
3RD
4RS
5CS
D–sub 25–pin on Omron PLC side
Pin no.
Abbreviation
SD SD
RD RD
RS RS
CS CS
GND GND
GT main unit side
Pin no.
Abbreviation
6
7SG
.
.
20 ER