MW800 Display Utilities
This application provides the following capabilities:
Calibration Tool calibrates the touch screen interface to the display
monitor
ExtraKey Application configures the MW800 display functional buttons
for other Windows applications
MW Display Tester troubleshoots several display problems
Volume Bar sets of the current volume level
Calibration
Sometimes there is a need to calibrate the touch panel attached to the display
monitor, i.e. to adjust the pushed position of the panel and its display position of the
monitor. Even if the touch panel has same dimensions as the display monitor, there
may be minor variations between corresponding data points due to resistance
variance of each panel.
When you use touch panel module for the first time, or, when there is discrepancy
between the touched and displayed positions, calibration is required. This needs to be
done only once, whereupon the calibration data is stored. The CPU will
automatically calculate the touched position on display monitor.
This adjustment may be executed with the MW800 Display Calibration Tool.
Figure 9. Calibration Window
This utility performs the following:
Calibrate Device calibrates the touch screen and saves calibration
data
Reset Device nullifies calibration parameters in the MW800
display codeplug
Simulate Calibration simulates calibration of the touch screen without
saving calibration
Test briefly tests of the touch screen after calibration