User guide

Release Notes
iC Web
48
iC Web
[Ref. #ICONTROL-13742] On client systems running Microsoft Windows 7 or Windows Vista,
you may not be able to load a Web browser in an iC Web zone.
Workaround:
Do one of the following two options:
•Disable the User Access Control (UAC) in Windows.
OR,
Enable the Windows2000 Compatibility mode on the Java executable file.
Some icons appearing in sites created by earlier versions of iC Creator will not be properly
sized or scaled when used with iControl version 3.00 (and later). To properly size and scale
all icons, simply use iC Creator to open and re-save each page.
iC Web sites that were created with iC Creator versions 2.0 or 2.2 can only be used with
version 3.00 (and later) if each individual page is opened and re-saved with iC Creator.
[Ref. #20976 / 21079] Certain combinations of OS, graphics card and Java version could have
an adverse impact on some Web sites’ graphics performance. For example, we found that
with a Dell laptop using the ATI Mobile X600 Radeon card, a Web sites performance
dropped significantly using Java 1.6 but was back to normal using Java 1.5. Using the
Windows compatibility mode set to Windows 2000 for the Java application when
running XP, or XP when running Vista also helped.
[Ref. #4871] It is not possible to replace the current home page with a new home page that
differs only in character case (say, http://host/mysite/aPage.mpf and
http://host/mysite/apage.mpf). Workarounds include clearing the home page
before setting the new one, or setting an intermediate home page before setting the new
one.
[Ref. #2588] It is not possible to embed multiple iC Navigator instances in an iC Web page.