Fixed in Version 4.12
Densité Services
[Ref. #31082] 3DX-3901: In the 3DX-3901 Control Panel, the Critical Health Failure alarm is
not visible in the Alarm Configuration panel.
[Ref. #33089] FIO-1901: In the FIO-1901 Control Panel, when attempting to copy a FIO-1901
card’s alarm profile to other cards, the other cards are not visible in the Copy to other
cards menu.
Fixed in Version 4.11
Densité Services
[Ref. #31472] HMP-1801: When selecting a Preload, a different clip than the one you chose
may cue and play.
[Ref. #23734] Audio-streaming may intermittently cut off due to audio loss packets. This may
result in an audible tick or pop.
General Status Manager
[Ref. #30603] Some GSM scripts do not load because functions within them are too long.
[Ref. #25866] When you select Offline as an operational mode for a disabled alarm in the
GSM Alarm Browser and then deselect Offline, the prefix iOMZ@ appears before the alarm
text.
iC Router Control
[Ref. #29634] Miranda’s implementation of the PESA USP router protocol does not support
multiple physical levels.
Redundancy / Failover
[Ref. #31460] After an Application Server failover, the Current IP attribute on the new Main
Application Server is not updated. Instead, the new Main’s Current IP remains Unknown.
IMPORTANT: The software resolution to this bug necessitates that in order for redundancy
to be fully functional, ONE of the following conditions must be true:
ALL the Application Servers within the Redundancy Group have iControl
version 4.10 or later installed.
ALL the Application Servers within the Redundancy Group have versions of
software earlier (and not including) iControl version 4.10 installed.
One implication of this is that when upgrading an Application Server to
version 4.10 or higher, you must similarly upgrade ALL Application Servers
within the Redundancy Group in order for redundancy to be functional.