The RMON driver is not backward compatible between versions 3.00 (and later) and 2.7:
Typical alarm URI in iControl 2.7 = //snmp:RMON/10.4.0.2/ifOperStatus101
Equivalent alarm URI in iControl 3.X = snmp://RMON:10.4.0.2/ifOperStatus101
iC Web sites using these alarms may need to be updated accordingly.
iControl Rollback is supported between same major versions only (e.g. between 2.74
and 2.73). The Rollback feature will not work between 3.xx and 2.7x.
iControl Web sites that were created with iC Creator versions 2.0 or 2.2 can only be used
with version 4.10 if each individual page is opened and re-saved with iC Creator.
As of iControl version 3.30, Imagestore alarm URIs consistently include a slash (
/), whereas
in the past some would have an at sign (
@) in their URI. iC Web sites using alarms such as
the following may need to be updated accordingly:
Mot_EMS.ImageStore.ImageStore_10.6.0.37@overall_status
Mot_EMS.ImageStore.ImageStore_10.6.0.37/overall_status
Mot_EMS.ImageStore.ImageStore_10.6.0.38@commStatus
Mot_EMS.ImageStore.ImageStore_10.6.0.38/commStatus
Mot_EMS.ImageStore.ImageStore_10.6.0.38@Temperature_status
Mot_EMS.ImageStore.ImageStore_10.6.0.38/Temperature_status
Mot_EMS.ImageStore.ImageStore_10.6.0.38@Version_not_compatible
Mot_EMS.ImageStore.ImageStore_10.6.0.38/Version_not_compatible
Mot_EMS.ImageStore.ImageStore_10.6.0.38@Voltage_status
Mot_EMS.ImageStore.ImageStore_10.6.0.38/Voltage_status
As of version 3.30, router configuration changes made in Router Manager Configurator are
not compatible with earlier versions of the software. Downgrading is supported but any
change to the router configuration made in version 3.30 or later will be lost during the
downgrade. After downgrading, any router configuration will have reverted to what it was
before the last upgrade.
SNMP trap listeners that use the enterprise OID are not compatible with traps sent from
iControl version 3.30 and later if they were configured in a system that had a version of
iControl between 3.00 and 3.22. If you wish the previous behavior to remain in effect, then
set the SNMPTrapPlugin.legacy.enterprise system property to True in
/usr/local/iControl/bin/conf/java_gsm.properties on the server. This property only
applies to the enterprise OID format.
Version Enterprise OID
before version 3.00 .1.3.6.1.4.1.3872.11.2
between versions 3.00 and 3.22 .1.3.6.1.4.1.3872
version 3.30 and later .1.3.6.1.4.1.3872.11.2