User`s guide

Debugging for DSP56800E
EOnCE Debugger Features
207Targeting MC56F83xx/DSP5685x Controllers
This pull down list lets you set the order in which a trigger and counter reaching
zero must occur to perform the action specified in Perform action.
Counter value
This edit box should be preloaded with a non-zero counter value when setting the
counter. The counter will proceed backward until a stop condition occurs. The
edit box will contain the value of the counter and will be updated whenever the
processor stops.
Trace Buffer
The trace buffer lets you view the target addresses of change-of-flow instructions that
the program executes. The trace buffer is configured with the
Trace Buffer Setup panel
(Figure 8.11
).
To open this panel:
1. From the IDE menu bar, select DSP56800E > Setup Trace Buffer.
Figure 8.11 Trace Buffer Setup Panel
To view the contents of the trace buffer (Figure 8.12
):